Leakage detection
TraceTek leakage warning and location system
The TraceTek system is a leakage warning and location system and is used to detect liquid leaks.
With the help of a sensor line and the associated evaluation units, contamination with a wide variety of liquids can be detected and located with meter accuracy. Its use is particularly important when you cannot see the area to be monitored, such as in raised floors (clean rooms, server rooms) or pipe runs in suspended ceilings.
It is also used in parallel with buried pipelines and for tank monitoring to detect oil leaks.
The TraceTek system’s unlimited application range, custom installation scheme and high flexibility allow a user to quickly and cleanly monitor however simple or complicated the requirements.
Whether you need a simple alarm system for a single room or a widespread warning and location system for a large area, there is a TraceTek system available to meet almost any requirement.
Avoid any risk. Find leaks before they find you!
The smallest amounts of liquid can cause downtime, malfunctions and costly damage. Why go through the inconvenience when you have the option of large-scale monitoring? Even very small leaks usually require a significant amount of cleanup and repair. TraceTek technology detects leaks on the spot and pinpoints their exact locations, allowing you to limit the damage before it spreads. TraceTek leak detection and locating systems have already proven their reliability in telecommunications centers, building services control centers, administrative and commercial institutions, libraries, hospitals, archives and museums.
Point sensors do not yet detect leakage …
…where tractek has long since sounded the alarm.
Why blanket surveillance?
With point monitoring, the leaking liquid must reach a sensor to trigger an alarm. Therefore, under unfavorable circumstances, a leak can spread considerably before it even reaches a point sensor.
With TraceTek, however, the liquid is detected as soon as it touches the sensor cable at any point.
Placing the cable in close proximity to potential trouble spots ensures that leaks are detected even earlier. The TTDM locating unit indicates the distance to the leak, allowing effective countermeasures to be taken immediately.
The TraceTek Leak Detection and Location System detects the leak immediately on site, an alarm sounds and the exact location of the damage appears on the display. Through the installation plan – which is part of the scope of delivery – you can see the leakage location.
Data centers and server rooms
In computer rooms, the sensor cable is looped in the raised floor near plumbing, water pipes, air conditioners and other sources of risk.
Networks
Network servers are often housed in rooms that are inadequately protected. To prevent leakage damage, the sensor cable is laid in raised floors and or collection troughs underneath pipe runs.
Switchboards
The TraceTek sensor cable protects telephone systems when installed underneath water pipes as well as along the perimeter trim of the room. Leaks can thus be detected early and corrected before a malfunction occurs.
Galleries and museums
Whatever the dangers to which your valuables may be exposed, the TraceTek system can be designed as a simple
warning or branched tracking system.
Basement rooms
Archives with sprinkler systems
The TraceTek sensor cable is installed in a collection trough under the pipes of the sprinkler system. Due to the direct monitoring of the water pipes, leaks can be detected immediately
Heating and air conditioning systems
When a leak is detected, the system can shut off the water supply via the relay contact, preventing costly damage to your office.
Shafts
TraceTek offers flexible routing options so that even widely separated rooms can be easily monitored and detected using T-junctions and area delimiters. Early detection is ensured by the sensor cables on all floors – the locating unit displays the exact position of the leak.
Technical rooms
Particularly critical areas
In the U.S., hydrocarbon sensing pipelines are listed in the standard API 1160 listed as mitigated facilities.
Connecting and transfer lines
Hydrant refueling systems at airports
Tank farms
Products
TTDM-128
Unit with locating, up to 192 km sensor line
TTA-SIM
Standalone module,
up to 150 m sensor cable
TT-SIM-1
Evaluation module
up to 1500 m sensor cable
TT-SIM-1A
Standalone module without display
up to 150 m sensor cable
TT-SIM-2
Standalone module with display
up to 150 m sensor cable
TT-SIM-iServer-24D
TT-VISU
TT-1000
For the detection of water.
TT-1100
highly flexible, for the detection of water.
For example, around pipes.
TT-3000
For the detection of acids and alkalis.
TT-5000
For the detection of hydrocarbons.
TT-5001
For locating special solvents.
TT-FFS
rapid fuel sensor
TT-MINI-PROBE
point sensor
TT-FLAT PROBE
TT-MET
End cap
TT-MLC
Connecting cable for SIM units
TT-MJC
Connecting cable in different lengths
TT-MBC
T-branch
TT-WL-4.5
area delimiter
TTE-XAL
External audible alarm
Zener-Barrier
For Ex-Zone
TT-HDC
Mounting clip
TT-TAG
Identification plate
TT-MAP-TOOL
Test brush
TT-FFS-FLOAT
Float for TT-FFS in steel, or plastic